This page goes deeper than Which analysis command when. It explains four techniques: how to find counters, how to read support maps, how forward fill joins signals that canair polled at different times, and how to find the same quantity in two places.

Counters: the one thing correlation cannot find

An odometer, an operating-hours tally, a power-cycle count and an uptime timer are all invisible to every tool above, for the same reason. Within any single session, a slow counter does not move. It has no variance to correlate and reads as a constant byte. What identifies it is its behaviour across the whole capture history: it never decreases.

investigate --counters sweeps every 1–4-byte window × endianness. It scores how much evidence there is that the window only rises, in bits. Each clean up-step with no down-step is one bit. So 8 bits means 8 rises and no falls (about a 1-in-256 coincidence). That single scale lets canair rank a densely-polled cumulative-Ah counter and an odometer read six times in a year together. The sparse counter is not lost under a step-count threshold.

canair groups the results by where the monotonicity lives, which is what names the signal:

Fingerprint Behaviour Typically
accumulator rises across the corpus and within sessions odometer, operating-seconds, cumulative Ah/Wh
cycle counter rises across the corpus but flat inside every session ignition / power-cycle / trip count
run timer ramps per session, resets to ~0, tracks wall-clock uptime, seconds-since-key-on
canair investigate CLU 22B002 --counters          # → [B12:B14] 70047 → 73048 (the odometer)
canair investigate BMS 2101 --counters            # → the five cumulative BMS registers
canair investigate BCM 22C011 --counters --unmapped-only   # only counters not settled yet
canair investigate --counters                     # sweep the WHOLE profile — every counter in the car
canair investigate BMS --counters                 # sweep every BMS PID

investigate sweeps when you omit the parameter identifier (PID). Give an electronic control unit (ECU), or a QUERY like "BMS:2101,2102", to sweep its captured PIDs. Give nothing to sweep the whole profile.

A sweep prints a ranked summary. For --counters, it is one list of every counter found. Otherwise it is one line per PID with the cheap local facts that mark a PID as worth a deep-dive. These facts are the varying and unmapped byte counts, the best state-separation F, and the physical-band hits. --top N caps the summary. The per-signal timelines (--events/--dwell/--field) stay single-PID.

--unmapped-only hides a window only when every signal that covers it is verified. canair keeps a window that an unverified guess maps, and tags it [NAME?]. Monotonicity is frequently the evidence that refutes the guess. For example, a byte labelled as a user-set hour that in fact only ever rises is a counter, not an hour. Hiding those windows would hide the finding.

canair forms multi-byte windows in ISO-TP space (the ISO 15765-2 transport protocol), where payload bytes are contiguous. It then renders them as a WiCAN expression. A counter that straddles a protocol control information (PCI) framing byte therefore comes out as an explicit shift composition (B14 | (B15 << 8) | (B17 << 16) | (B18 << 24)), and not as a wrong [Bn:Bm] range. See Byte indexing.

One physical counter makes every prefix window monotonic too (dropping the low byte divides by 256). canair therefore collapses nested hits to one representative: the widest window whose end bytes are not padding. The width recovers the readable magnitude. [B12:B14] = 72982 is instantly an odometer. Its low byte alone (B14 = 88) says nothing.

This is the one analysis you should not scope

Unlike everything else on this page, --counters wants the whole history. A --state or --since filter shortens the horizon, and the horizon is the evidence. canair therefore warns on stderr about a scope filter (and flags scoped: true in --json), because the filter understates the bits ranking. Narrow the scope only to exclude known-bad data. If the report is empty, it names the best sub-threshold window and the --min-bits value that would show it. A dead end then still points somewhere.

--counters currently works on uds (diagnostic PIDs read through Unified Diagnostic Services) only. The raw broadcast Controller Area Network (CAN) counterpart is not implemented.

Support maps: which bits are signals at all

Some body and climate data identifiers (DIDs) start their data with a few constant bytes. These bytes say which of the bits (or bytes) that follow are real signals. On the bundled Ioniq, the 22BC03–22BC07 DIDs of the IGPM read 62 BC03 FD EE 3C 73 …. The four bytes never change. They map bit 7 of the first byte to data bit 0 of the first covered byte, bit 6 to bit 1, and so on.

Every bit that ever moves in about 1,750 captures per DID falls on a marked position. A bit outside the map never moves. HVAC 220100 uses the coarser form: one map bit per data byte.

canair investigate IGPM --support-map        # every IGPM DID: map, open signals, verdict
canair investigate BCM 22B005 --support-map  # one DID, including why a fit is refused
canair pids set-support-map IGPM 22BC03 --at 0 --length 4 --unit bit   # declare it

For each DID, canair reports the verdict. For the signals that the map marks, it reports which are defined and which are open. Open signals split into moving, always on and never set. A marked bit that nobody has exercised yet is where the next body signal is hiding. canair also lists defined signals that the map does not mark, which deserve a second look.

How far to trust a fit:

Verdict Meaning
STRONG consistent with the map and very unlikely to be chance on its own
CORROBORATED consistent, but convincing only together with sibling DIDs of the same ECU that share the placement
WEAK consistent, but too little moving data to say more
REJECTED set bits (or live bytes) outside the map; canair shows the closest fit but does not propose it

The score is the probability that an unrelated map would fit this well. It is C(m, s) / C(8, s) per byte for m marked bits of which s ever move. canair multiplies it across the map and charges it for every placement tried. A single DID with a handful of moving bits can never be significant alone, which is why siblings corroborate each other. A DID that breaks the layout counts against them, not for them.

A marked bit may be the start of a multi-bit field. canair therefore reports an unmarked bit directly above a mark as a field continuation, not a violation (the left/right turn signal of the IGPM is one 2-bit field).

Field maps: one bit per parameter

The service-21 pages (BMS, VCU, MCU, OBC) lead with constant bytes too. Each bit marks one field of the page, in order, whatever its width. A field is a span of bytes that the map marks. It is not a signal, because the map can mark a field that no signal reads yet.

Hyundai's own diagnostics spec defines the bitmap this way. The per-bit and per-byte layouts above are its special cases, where every field is one bit or one byte. A record with more than 32 fields carries a further bitmap as field 32, 64, and so on.

The map gives the number of fields, not their widths. --support-map therefore splits the bytes using the defined signals:

  • A defined signal is never cut.
  • The bytes of an unmarked field must never change.
  • Every marked field must exist.
Verdict Meaning
EXACT the bytes split into fields exactly one way
CONSISTENT several splits fit (the bytes that no signal reads group more than one way)
BROKEN no split fits; shown as a per-field reading note under the other fits

What this gives you on a new car:

  • open, marked: a marked field that no signal reads yet. On the Ioniq, BMS 2101 (32 fields) has exactly one open field, and VCU 2101 (11 fields) has one open field. Run canair investigate ECU PID --support-map to list them.
  • unsupported / fill: the bytes of an unmarked field are fill on this unit, not a signal that never moved. On the Kona, the fill of BMS 220101 is a fifth module temperature and the battery-fan fields, which a liquid-cooled pack lacks.
  • the count itself: N marks over W bytes means W − N bytes belong to multi-byte fields, before any correlation.
  • more bitmaps: further bitmaps in a long record (Ioniq BMS 21F2 has one at data+48).

The spec counts from the most significant bit. Where that reading is broken and the least significant bit first fits (the Ioniq MCU's 00 00 03 FF), the report says LSB first.

When the captures carry several maps for one PID (two cars, two software versions), canair fits each on its own rows and reports them as VARIANTS, with the map bits that differ.

Trust, absence and declaring

This is not make-wide. BCM 22B005 is a hard exception: its light-stalk bits move outside its map. That is why you declare a map per PID after you read the report, and canair does not apply it automatically. No map has turned up on a Nissan or XPeng profile.

A PID with no fit says why, and that is information too. Leading bytes vary means the data starts right after the DID echo, so the first bytes are signals, not a map. The other reasons mean that the captures cannot tell: constant 00, constant FF, nothing moving, too few captures, or a few fixed values that differ between cars or sessions. A sweep prints the count of each on its header line.

Once you declare a map (canair pids set-support-map, with --unit field and, where reported, --order lsb or --also-at), canair coverage reads the map off each payload:

  • The bytes of the map itself, and the bytes it marks as carrying nothing, stop being reported as UNMAPPED.
  • BITS counts only marked bits.
  • Signals that read unmarked positions are reported as OUTSIDE MAP.
  • A field map adds a FIELDS line (marked fields against defined ones) and OPEN FIELDS.

canair bix --annotate --ecu --pid labels the map bytes in a payload. canair monitor, canair read and canair captures uds --step/--diff draw them in a muted grey-blue. See plans/2026-10-29-support-bitmap-coverage.md and plans/2026-11-03-support-map-field-maps.md for the design and the evidence.

Forward fill: a run-length row is a segment, not a sample

A keep:changes row means "the value changed to this, and stays this until the next row". The time-aligned joins used to treat it as a point measurement. A signal that legitimately did not change then had nothing to attach to, and canair silently dropped the row.

Measured on the bundled profile: aligning the charge-port lock of the IGPM against BMS SOC joined 5 of 2016 rows. The lock was known with certainty for a whole 3 h charge, in which it changed exactly twice. That is a 99.75 % loss of a window that was never unknown.

align, correlate, hunt, investigate and decode therefore carry a run-length value forward to reference instants where it has no sample:

Flag Effect
--fill auto Default. Fills only rows from keep:changes sessions. It decides per row, so a scope that spans a run-length session and a keep:unique session fills only the part it may
--fill hold Forces the fill everywhere (legacy or keep:all data, whose provenance is unrecorded). Warns loudly on keep:unique, where global dedup genuinely destroyed the run structure
--fill none Strict point semantics: the behaviour before the fill existed, for comparison
--max-hold SECONDS Caps the carry (default: until the next row or the end of its recording session)

canair never carries a value across a session boundary, because the ECU may have changed unobserved between two recordings. The final run of a session closes when that session stopped recording, not at the last capture of the PID.

canair always reports filling, because a filled row is reconstructed rather than measured:

  • align shows a per-column [N joined + M held, up to 2h58m] and marks filled per row in --json.
  • correlate/hunt/investigate name the run-length signals they carried forward, in text and in a --json fill block.
  • --csv stays a pure numeric table and reports the carry on stderr instead.

A narrow time window can hide a run-length signal entirely

Scope filters run before canair computes the validity windows. --since 13:00 --until 13:01 therefore excludes the earlier row that established the value held through that minute, and the signal then appears absent. Scope by --date, --state or --last-session (which keep whole sessions) when a run-length signal is involved.

Correlation magnitudes change under fill

A filled candidate contributes many repeated values, so |r| reflects the step-wise reconstruction. The strict join kept only the handful of transition instants. The filled number is more honest, because the strict join silently restricted the comparison to transitions, which inflates |r|. But it is a different number. Weighting statistics by segment duration is deliberately a follow-up (see plans/2026-08-05-run-length-forward-fill-joins.md).

Mirrors: the same quantity reachable two ways

A mirror is one physical value that two signals expose. Examples are a status bit that one ECU publishes and another repeats, a temperature that a second module reports at a different offset, and a raw byte with the signal derived from it. A mirror is the fastest possible identification of an unknown byte, because it needs no correlation reasoning: the byte is the known signal.

  • decode --find-mirrors — within one PID (rows aligned by capture, no time join)
  • correlate --find-mirrors — across co-polled ECU/PIDs, time-aligned
  • correlate can --find-mirrors — across arbitration IDs in a frame log

Two knobs are shared by all three:

Flag Why
--mirror-match FRACTION (default 0.9) Round-robin polling reads a drifting signal on two ECUs seconds apart, so they disagree by ±1 on a minority of rows. Demanding every row (--mirror-match 1) hides most real mirrors on its own
--allow-offset Real mirrors are frequently the same quantity at a different zero or in different units. AAF:2181:AAF_OBC_TEMP + 100 is the raw temperature byte of the OBC. A raw 12 V byte is × 12.8 the decoded rail

Raw agreement alone is not evidence. A pair must also agree better than coincidence (Cohen's κ, reported whenever agreement is not unanimous). Without that floor, two flags that are both zero in 99 % of rows "agree" 99 % of the time by construction. On the bundled profile, that turned 3 real mirrors into 73 reported pairs.

Bimodal references defeat correlation ranking

When a reference signal collapses into two flat, well-separated clusters, correlation stops being useful for identifying a signal. An example is a 12 V bus that sits at ~14.5 V while charging and ~12.2 V otherwise, with little variation within each level.

Any candidate byte that merely differs between the two regimes then correlates near-perfectly (|r|≈1). All the apparent "signal" is the single between-cluster jump that every regime-discriminating byte shares (a two-cluster / point-biserial artifact). So hunt --against and correlate --against rank cluster separation, not a real match, and the top hits are meaningless.

hunt and correlate warn when the reference is bimodal. When you see the warning (or suspect the problem), do not trust the ranking. Instead, do one or both of these:

  • Scope to data with continuous variation in the reference (a keep-all drive where the 12 V or temperature actually sweeps a range), not a two-state regime flip.
  • Anchor on absolute value rather than correlation. A real signal must match the known physical value at each regime (for example, read ≈12.2 in ON and ≈14.5 while charging). A spurious regime-discriminator will not.

A continuously-varying reference is not flagged. Vehicle speed is an example: it is flat at 0 while parked, then a wide moving cluster. The gap there does not dominate the spread of the moving cluster, so correlation against it stays meaningful.

Related: the reverse trap on a monotonic scope (a single long charge where everything slowly rises). Every rising byte correlates too. A regime exit (the post-charge cool-down) breaks it: real temperatures fall, counters do not.